Freescale Semiconductor, Inc.
STATIC ELECTRICAL CHARACTERISTICS
Characteristics noted under conditions 3.1 V SOPWR 5.5 V, 5.0 V VPWR 18 V, -40°C TC 125°C unless otherwise noted.
Where applicable, typical values noted reflect the parameter ‘s approximate value with VPWR = 13 V, TA = 25°C.
Characteristic
Symbol
Min
Typ
Max
Unit
POWER SUPPLY
Supply Voltage Range
Fully Operational
VPWR (FO)
V
5.0
27
Supply Current
All Outputs ON, IOUT = 0.3 A
IPWR (ON)
mA
4.0
8.0
Sleep State Supply Current at RST 0.2 SOPWR and/or
IPWR (SS)
-10
1.0
10
µA
SOPWR 0.5 V
Overvoltage Shutdown
VOV
27.5
31.5
35
V
Overvoltage Shutdown Hysteresis
VOV (HYS)
0.8
1.4
2.3
V
VPWR Undervoltage Shutdown
VPWR (UV)
3.2
3.5
V
SPI Interface Logic Supply Voltage
SOPWR
3.1
5.5
V
SPI Interface Logic Supply Current (RST Pin High)
ISOPWR(RSTH)
100
500
µA
SPI Interface Logic Supply Current (RST Pin Low)
ISOPWR(RSTL)
-10
10
µA
SPI Interface Logic Supply Undervoltage Lockout Threshold SOPWR(UNVOL)
2.0
2.5
3.0
V
POWER OUTPUT
Drain-to-Source ON Resistance (IOUT = 0.35 A, VPWR = 13 V)
RDS(ON)
TJ = 125°C
TJ = 25°C
TJ = -40°C
0.75
1.2
0.55
1.2
0.45
1.2
Output Self-Limiting Current
Outputs Programmed ON
I OUT (lim)
A
0.9
1.2
2.5
Output Fault Detect Threshold (Note 11)
Outputs Programmed OFF
VOUTth (F)
V
2.5
3.0
3.5
Output Off Open Load Detect Current (Note 12)
Outputs Programmed OFF (VPWR = 5.0 V)
Outputs Programmed OFF (VPWR = 13 V, 18 V)
I OCO(5)
25
I OCO(13,18)
30
µA
50
100
50
100
Output Clamp Voltage
IOUT = 20 mA
Output Leakage Current
SOPWR 2.0 V
VCL
V
45
50
55
IOUT(lkg)
µA
-10
2.0
10
Overtemperature Shutdown (Outputs OFF) (Note 13)
TLIM
155
165
180
°C
Overtemperature Shutdown Hysteresis (Note 13)
TLIM (hys)
5.0
10
20
°C
Notes
11. Output Fault Detect Thresholds with outputs programmed OFF. Output Fault Detect Thresholds are the same for output open and shorts.
12. Output OFF Open Load Detect Current is the current required to flow through the load for the purpose of detecting the existence of an open
load condition when the specific output is commanded to be OFF.
13. This parameter is guaranteed by design but not production tested.
MOTOROLA ANALOG INTEGRATED CIRFCoUrITMDoErVeICEInDfAoTrAmation On This Product,
Go to: www.freescale.com
33996