DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MB3775 Ver la hoja de datos (PDF) - Fujitsu

Número de pieza
componentes Descripción
Fabricante
MB3775 Datasheet PDF : 30 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
MB3775
HOW TO SET OUTPUT VOLTAGE
The output voltage is set using the connection shown in Fig. 5 and 6.
The error amplifiers are supplied to the internal reference voltage circuit as are the other internal circuits. The
common-mode input voltage range is from 0.2 V to +1.45 V.
When the amplifiers are operated non-inverting, tie the inverting terminal to VREF ( 1.28 V). When the amplifiers
are operated inverting, tie the non-inverting terminal to ground.
Fig. 5 -Connection of Error Amp
Output Voltage V0 is plus
R2
V0+ [V0+ = VREF X (1 + R2/R1)]
+
R1
PIN 5 or PIN 12
VREF
R1
VREF
Fig. 6 -Connection of Error Amp
Output Voltage V0 is minus
R2
V0- [V0- = VREF X (R2/R1)]
PIN 5 or PIN 12
+