DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

LS4899-7B1 Ver la hoja de datos (PDF) - Power-One Inc.

Número de pieza
componentes Descripción
Fabricante
LS4899-7B1
Power-One
Power-One Inc. Power-One
LS4899-7B1 Datasheet PDF : 27 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
Cassette Style
100 Watt AC-DC Converters
S Series PFC
Electromagnetic Compatibility (EMC)
A metal oxide VDR together with an input fuse and an input
filter form an effective protection against high input tran-
sient voltages which typically occur in most installations.
The S series has been successfully tested to the following
specifications:
Electromagnetic Immunity
Table 8: Immunity type tests
Phenomenon Standard 1 Level
Coupling
mode 2
Value
applied
Waveform Source
imped.
Test
procedure
In Per-
oper. form. 3
Voltage surge IEC 60571-1
Supply related RIA 12
B
surge
i/c, +i/i
+i/i
800 Vp
1500 Vp
3000 Vp
4000 Vp
7000 Vp
1.5 Ubatt
100 µs
50 µs
5 µs
1 µs
100 ns
1s
100 1 pos. and 1 neg. yes 4
voltage surge per
coupling mode
0.2
1 positive
surge
yes
4
Direct transient
Indirect coupled
transient
Electrostatic
discharge
(to case)
IEC/EN
61000-4-2
C
+i/c, i/c
960 Vp
10/100 µs
5 5 pos. and 5 neg. yes 4
D
1800 Vp
5/50 µs
impulses
E
3600 Vp
0.5/5 µs
100
F
4800 Vp
0.1/1 µs
G
8400 Vp 0.05/0.1 µs
H
o/c, +o/c
1800 Vp
5/50 µs
J
3600 Vp
0.5/5 µs
K
4800 Vp
0.1/1 µs
L
8400 Vp 0.05/0.1 µs
4 contact discharge 8000 Vp
air discharge 15000 Vp
1/50 ns
330 10 positive and yes A
10 negative
discharges
Electromagnetic IEC/EN
3
field
61000-4-3
antenna
10 V/m
AM 80%
1 kHz
n.a. 801000 MHz yes A
Electromagnetic ENV 50204
field,
pulse modulated
50% duty cycle,
200 Hz repetition
frequency
900 ±5 MHz
yes A
Electrical fast IEC/EN
transient/burst 61000-4-4
4
capacitive, o/c 2000 Vp bursts of 5/50 ns 50
1 min positive yes A
i/c, +i/i
direct
4000 Vp
2.5/5 kHz over
15 ms; burst
period: 300 ms
1 min negative
A
transients per
coupling mode
Surge
IEC/EN
3
61000-4-5
4
i/c
2000 Vp
1.2/50 µs
12 5 pos. and 5 neg. yes A
+i/i
2
surges per
Conducted
disturbances
IEC/EN
61000-4-6
i/c, +i/i
2500 Vp
10/700 µs
3 i, o, signal wires 10 Vrms
AM 80%
(140 dBµV)
1 kHz
40
150
0.15...80 MHz
yes A
1 Related and previous standards are referenced in: Technical Information: Standards.
2 i = input, o = output, c = case.
3 A = Normal operation, no deviation from specifications, B = Normal operation, temporary deviation from specs possible.
4 Test in progress, please consult factory.
Note: Previous standards are referenced in: Technical In-
formation: Standards
Edition 01/01.2001
15/27

Share Link: 