LD18123A-13
12.Handling Precautions
a) Be sure to turn off the power supply when inserting or disconnecting the cable.
b) Be sure to design the cabinet so that the module can be installed without any extra stress such as
warp or twist.
c) Since the front polarizer is easily damaged, pay attention not to scratch it.
d) Wipe off water drop immediately. Long contact with water may cause discoloration or spots.
e) When the panel surface is soiled, wipe it with absorbent cotton or other soft cloth.
f) Since the panel is made of glass, it may break or crack if dropped or bumped on hard surface.
Handle with care.
g) Since CMOS LSI is used in this module, take care of static electricity and injure the human earth
when handling.Observe all other precautionary requirements in handling components.
h) Since there is a circuit board in the module back, stress is not added at the time of a design assembly.
Please make it like. If stress is added, there is a possibility that circuit parts may be damaged.
i) Protection film is attached to the module surface to prevent it from being scratched .
Peel the film off slowly , just before the use, with strict attention to electrostatic charges.
Blow off 'dust' on the polarizer by using an ionized nitrogen.
j) The polarizer surface on the panel is treated with Anti-Glare for low reflection. In case of attaching
protective board over the LCD, be careful about the optical interface fringe etc. which degrades
display quality.
k) Do not expose the LCD panel to direct sunlight. Lightproof shade etc. should be attached when LCD
panel is used under such environment.
l) Connect GND to 4 place of mounting holes to stabilize against EMI and external noise.
m) There are high voltage portions on the backlight and very dangerous. Careless touch may lead to
electrical shock. When exchange lamps or service, turn off the power without tail.
n) When handling LCD modules and assembling them into cabinets, please be noted that long-term
storage in the environment of oxidization or deoxidization gas and the use of such materials as
reagent,solvent, adhesive, resin, etc. which generate these gasses, may cause corrosion and
discoloration of the LCD modules.
o) Cold cathode fluorescent lamp in LCD panel contains a small amount of mercury, please follow local
ordinances or regulations for disposal.
p) Be careful of a back light lead not to pull by force at the time of the wiring to an inverter,
or line processing.
q) When install LCD modules in the cabinet, please tighten with “torque=0.294±0.02Nm(3.0±0.2kgfcm)”.
r) Liquid crystal contained in the panel may leak if the LCD is broken. Rinse it as soon as possible if it
gets inside your eye or mouth by mistake.
s) Notice:Never dismantle the module , because it will cause failure.
t) Be careful when using it for long time with fixed pattern display as it may cause afterimage.
u) Adjusting volume have been set optimally before shipment, so do not change any adjusted value.
If adjusted value is changed, the specification may not be satisfied.
v) If a minute particle enters in the module and adheres to an optical material, it may cause display non-
uniformity issue, etc. Therefore, fine-pitch filters have to be installed to cooling and inhalation hole if
you intend to install a fan.
13. Packing form
Product countries / Areas
Piling number of cartons
Package quantity in one carton
Carton size
Total mass of one carton filled
with full modules
Packing form is shown
JAPAN
TAIWAN
CHINA
6
10pcs
388(L) x 334(W) x 263(H)
10,000g