LM135-LM235-LM335,A
THERMOCOUPLE COLD JUNCTION COMPENSATION
(compensation for grounded thermocouple)
+15V
4.7kΩ
200kΩ
R2
1%
R3*
1N4568 10
kΩ
1MΩ
1%
LM135
LM235
LM335
R1
10kΩ
12kΩ
71.5kΩ
1%
Th ermo-
couple
J
T
K
S
R3
377Ω
308Ω
293Ω
45.8Ω
Seebeck
Coefficient
52.3µV/oC
42.8µV/oC
40.8µV/oC
6.4µV/oC
Adjustments : compensates for both sensor
and resistor tolerances.
1. Short 1N4568.
2. Adjust R1 for SEEBECK coefficient times
ambient temperature (in degrees K) across
R3.
3. Short LM135 and adjust R2 for voltage
across R3 corresponding to thermocouple
type.
J 14.32mV
K 11.17mV
T 11.79mV
S 1.768mV
Thermocouple
-15V
* Select R3 for proper thermocouple type
SINGLE POWER SUPPLY COLD JUNCTION COMPENSATION
+15V
10kΩ
200kΩ
LM135
LM235
LM335
R1
R3*
10kΩ
+15V
Thermo-
couple
J
T
K
S
R3
1.05kΩ
856Ω
816Ω
128Ω
R4
365Ω
315Ω
300Ω
46.3Ω
Seebeck
Coefficient
52.3µV/oC
42.8µV/oC
460..48µµVV//ooCC
Thermocoup le
Adjustments :
1. Adjust R1 for the voltage across R3 equal
to the SEEBECK coefficient times ambient
temperature in degrees Kelvin.
2. Adjust R2 for voltage across R4 correspon-
ding to thermocouple.
J 14.32mV
K 11.17mV
T 11.79mV
S 1.768mV
1N4568
R2
10
kΩ
200kΩ
1MΩ
Output
R4*
* Select R3 and R4 for proper thermocouple
9/11