DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

LH28F800BJHE-PTTL90 Ver la hoja de datos (PDF) - Sharp Electronics

Número de pieza
componentes Descripción
Fabricante
LH28F800BJHE-PTTL90
Sharp
Sharp Electronics Sharp
LH28F800BJHE-PTTL90 Datasheet PDF : 47 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
LHF80J03
11
Table 3. Command Definitions(10)
Command
Bus Cycles
Req’d. Notes
First Bus Cycle
Oper(1) Addr(2) Data(3)
Second Bus Cycle
Oper(1) Addr(2) Data(3)
Read Array/Reset
1
Write
X
FFH
Read Identifier Codes
2
4
Write
X
90H
Read
IA
ID
Read Status Register
2
Write
X
70H
Read
X
SRD
Clear Status Register
1
Write
X
50H
Block Erase
2
5
Write
X
20H
Write
BA
D0H
Full Chip Erase
2
Write
X
30H
Write
X
D0H
Word/Byte Write
2
5,6
Write
X
40H or
10H
Write
WA
WD
Block Erase and Word/Byte
Write Suspend
1
5
Write
X
B0H
Block Erase and Word/Byte
Write Resume
1
5
Write
X
D0H
Set Block Lock-Bit
2
8
Write
X
60H
Write
BA
01H
Clear Block Lock-Bits
2
7,8
Write
X
60H
Write
X
D0H
Set Permanent Lock-Bit
2
9
Write
X
60H
Write
X
F1H
OTP Program
2
Write
X
C0H Write
OA
OD
NOTES:
1. BUS operations are defined in Table 2.1 and Table 2.2.
2. X=Any valid address within the device.
IA=Identifier Code Address: see Figure 4.
BA=Address within the block being erased or locked.
WA=Address of memory location to be written.
OA=Address of OTP block to be written: see Figure 5.
3. ID=Data read from identifier codes.
SRD=Data read from status register. See Table 6 for a description of the status register bits.
WD=Data to be written at location WA. Data is latched on the rising edge of WE# or CE# (whichever goes high first).
OD=Data to be written at location OA. Data is latched on the rising edge of WE# or CE# (whichever goes high first).
4. Following the Read Identifier Codes command, read operations access manufacturer, device, block lock configuration and
permanent lock configuration codes. See Section 4.2 for read identifier code data.
5. If WP# is VIL, boot blocks are locked without block lock-bits state. If WP# is VIH, boot blocks are locked by block lock-
bits. The parameter and main blocks are locked by block lock-bits without WP# state.
6. Either 40H or 10H are recognized by the WSM as the word/byte write setup.
7. The clear block lock-bits operation simultaneously clears all block lock-bits.
8. If the permanent lock-bit is set, Set Block Lock-Bit and Clear Block Lock-Bits commands can not be done.
9. Once the permanent lock-bit is set, permanent lock-bit reset is unable.
10. Commands other than those shown above are reserved by SHARP for future device implementations and should not be
used.
Rev. 1.27

Share Link: 