LA76075
VIF Block Input Signals and Measurement Conditions
1. Input the input signals to the VIF IN pin noted on the measurement circuit diagrams.
2. The input signal levels are the VIF IN levels noted on the measurement circuit diagrams.
3. The following table describes the input signals.
Input Signal
Waveform
Conditions
SG1
45.75 MHz
SG2
42.17 MHz
SG3
41.25 MHz
SG4
Variable frequency
SG5
45.75 MHz
87.5% Video Mod.
Ten-step wave using 3.58-MHz
subcarrier
SG6
45.75 MHz
87.5% Video Mod.
Flat field signal
4. Before starting the measurements, adjust the digital-to-analog converters in the following order.
Item
APC DAC
PLL DAC
Video Level DAC
Measurement Point
13
13
45
Input Signal
No signal, IF.AGC.DEF = 1
SG1, 93 dBµ
SG6, 93 dBµ
Target Value
Adjust to bring the DC voltage at pin 13 as close as possible to 3.8 V.
Adjust to bring the DC voltage at pin 13 as close as possible to 3.8 V.
Adjust to bring the output level at pin 45 as close as possible to 2.0 Vp-p.
No. 5845-13/35