L6562A
Application examples and ideas
Figure 22. L6562A 80W TM PFC evaluation Figure 23. L6562A 80W TM PFC evaluation
board: compliance to EN61000-3-2
board: compliance to JEIDA-MITI
standard
standard
Measurements @ 230Vac Full load EN61000-3-2 class D limits
1
Measurements @ 100Vac Full load JEIDA-MITI class D limits
1
0.1
0.1
0.01
0.01
0.001
0.001
0.0001
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
Harmonic Order (n)
0.0001
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
Harmonic Order (n)
Vin = 230 Vac - 50 Hz, Pout = 80 W
THD = 10.48 %, PF = 0.973
Vin = 100 Vac - 50 Hz, Pout = 80 W
THD = 3.18 %, PF = 0.997
Figure 24. Figure 3 - L6562A 80W TM PFC
Evaluation board: Input Current
waveform @230V-50Hz – 80W load
Figure 25. Figure 4- L6562A 80W TM PFC
Evaluation board: Input Current
waveform @100V-50Hz – 80W load
19/26