Electrical Specifications
Over Recommended Operating Conditions (TA = –40qC to +85qC , 2.7V d VCC d 3.6V) unless otherwise specified.
All Typicals at VCC = 3.3 V, TA = 25qC. All enable test conditions apply to single channel products only. See Note 5.
Parameter
Sym. Device Min. Typ. Max. Units Test Conditions
Fig.
Note
High Level
Output Current
Input Threshold
Current
Low Level
Output Voltage
High Level
Supply Current
Low Level
Supply Current
High Level
Enable Current
IOH*
ITH
VOL*
ICCH Single
Dual
ICCL
Single
Dual
IEH
Single
4.5 50
μA
VCC = 3.3 V, VE = 2.0 V,
1
VO = 3.3 V, IF = 250 μA
3.0 5.0 mA VCC = 3.3 V, VE = 2.0 V,
2
VO = 0.6 V,
IOL (Sinking) = 13 mA
0.35 0.6 V
VCC = 3.3 V, VE = 2.0 V,
3
IF = 5 mA,
IOL (Sinking) = 13 mA
4.7 7.0 mA VE = 0.5 V IF = 0 mA
6.9 10.0
VCC = 3.3 V
7.0 10.0 mA VE = 0.5 V IF = 10 mA
8.7 15.0
VCC = 3.3 V
–0.5 –1.2 mA VCC = 3.3 V, VE = 2.0 V
1, 15
15
15
Low Level
Enable Current
IEL*
Single
–0.5 –1.2 mA VCC = 3.3 V, VE = 0.5 V
High Level
VEH
Single 2.0
V
15
Enable Voltage
Low Level
Enable Voltage
VEL
Single
0.8 V
Input Forward
VF
Voltage
1.4 1.5 1.75* V
TA = 25˚C, IF = 10 mA
5
1
Input Reverse
BVR*
5
V
IR = 10 μA
1
Breakdown
Voltage
Input Diode
∆VF/
–1.6
mV˚C IF = 10 mA
1
Temperature
∆TA
Coefficient
Input
CIN
Capacitance
60
pF
f = 1 MHz, VF = 0 V
1
*The JEDEC Registration specifies 0˚C to +70˚C. Avago specifies –40˚C to +85˚C.
9