DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

HB28H016MM2 Ver la hoja de datos (PDF) - Renesas Electronics

Número de pieza
componentes Descripción
Fabricante
HB28H016MM2 Datasheet PDF : 90 Pages
First Prev 21 22 23 24 25 26 27 28 29 30 Next Last
HB28H016/D032/B064/B128MM2
The command transmission always starts with the MSB. Each command starts with a start bit and ends with
a 7-bit CRC command protection field followed by an end bit. The length of each command frame is fixed
to 48 bits (2.4 µs at 20 MHz):
0
1
bit5...bit0 bit31...bit0
start bit host command argument
Note: 1. (Cyclic Redundancy Check)
bit6...bit0
CRC*1
1
end bit
The start bit is always 0in command frames (sent from host to MultiMediaCard). The host bit is always
1for commands. The command field contains the binary coded command number. The argument
depends on the command (refer to Table Basic Commands (class 0) and Table Block-Oriented Read
Commands (class 2)). The CRC field is defined in Chapter Cyclic Redundancy Check (CRC).
Rev.5.0, Jan. 2003, page 25 of 88