RELIABILITY TESTING
◆Items of Reliability Testing
No.
Test item
Test condition
1
Operation in
high temperature
2
Shelf test in
high temperature
Ta = +50°C all display on
(standard operation)
Ta = +70°C
(no operation)
3
Shelf test in
low temperature
Ta = ‑20°C
(no operation)
4
High‑temperature,
high‑humidity test
Ta = +40°C,RH=90%
(no operation)
5
Temperature cycle
test
‑20℃(30min.) ⇒ +25℃(5min.) ⇒ +70℃(30min)
+25℃(5min.)
(no operation)
6 Vibration test
Frequency range:10〜55Hz
Total amplitude:1.5mm
Sweep ratio :10〜55〜10 about 1 minute
Standard
:JIS C 60068‑2‑ 6:1999
(no operation)
7 Mechanical shock
Peak acceleration:50 x 9.8 m/s2
Length of impact application:
11msec Half sine wave
Standard
:JIS C 60068‑2‑27:1995
(no operation)
Test hours
240hours
240hours
240hours
240hours
10cycles
2 hours
for each
direction of
x, y and z
(total 6 hours)
3 times for
each direction of
±X, ±Y and ±Z
◆Criteria
Visually check the display quality using an LCD module inspection tool.
a) Miss or no function of display.
b) Damaging or deforming of components.
2005.05.25