AC ELECTRICAL CHARACTERISTICS OVERDRIVE SPEED
PARAMETER
SYMBOL MIN TYP MAX
Time Slot
Write 1 Low Time
Write 0 Low Time
Read Data Valid
Release Time
Read Data Setup
Recovery Time
Reset Time High
Reset Time Low
Presence Detect High
Presence Detect Low
tSLOT
tLOW1
tLOW0
tRDV
tRELEASE
tSU
tREC
tRSTH
tRSTL
tPDH
tPDL
6
16
1
2
6
16
exactly 2
0
1.5
4
1
1
48
48
80
2
6
8
24
DS1996
(-40°C to 70°C)
UNITS NOTES
µs
µs
µs
µs
µs
µs
5
µs
µs
4
µs
µs
µs
NOTES:
1. All voltages are referenced to ground.
2. VPUP = external pullup voltage.
3. Input load is to ground.
4. An additional reset or communication sequence cannot begin until the reset high time has expired.
5. Read data setup time refers to the time the host must pull the 1-Wire bus low to read a bit. Data is
guaranteed to be valid within 1 µs of this falling edge.
6. Capacitance on the data contact could be 800 pF when power is first applied. If a 5 kΩ resistor is used
to pullup the data line to VCC, 5 ms after power has been applied, the parasite capacitance will not
affect normal communications.
7. The reset low time (tRSTL) should be restricted to a maximum of 960 µs, to allow interrupt signaling,
otherwise, it could mask or conceal interrupt pulses.
8. VIH is a function of the external pullup resistor and the VCC power supply.
18 of 18