DS1205S
NOTES:
1. All voltages are referenced to ground.
2. VIH = 2.0V or VIL = 0.8V with 10 ns maximum rise and fall time.
3. VOH = 2.4V and VOL = 0.4V.
4. Load capacitance = 50 pF.
5. Measured with outputs open.
6. (Normal battery backup operation) VCC1 = 5.0 Volts + 10%; VBAT = 3.0 Volts.
7. (Battery operate mode) VCCO = 3.0 Volts.
8. Per transaction (512 bits + protocol).
9. An additional reset or communication sequence cannot begin until the reset high time has expired.
10. Read data setup time refers to the time the host must pull the 1-wire pin low to read a bit. Data is guaranteed
to be valid within 1 µS of this falling edge and will remain valid for 14 µS minimum (15 µS total falling edge on
1-wire).
11. VCCO = VCCI - 0.3V
021798 17/17