Application Information, cont’d.
Use with Negative Ground
Either the HV301 or HV311 may be used with any negative
ground systems where DC/DC PWM Converters have isolated
outputs and their inputs need not be ground referenced
(Application Circuit 14).
HV301/HV311
Current Limit Stability (Method 2 (Servo) Only)
The closed loop current mode control system used in the HV301/
HV311 is very stable, especially when driving MOSFETs with
high gate capacitances (CISS). However, a peaking in ILIMIT near
the end of the current limit may be noted with some MOSFETs.
The current control loop can be frequency compensated to
eliminate this peaking by adding a series connected capacitor
and resistor between the gate and source of the external MOSFET.
The recommended starting values for C and R are 10nF and 1K.
These compensation values should be verified by board level
testing, which may yield satisfactory results with reduced com-
ponent values.
+48V
R1
487k
R2
6.81k
R3
9.76k
8
VDD
3
UV
2
OV
PWRGD / PWRGD 1
HV301/
HV311
ENABLE/ ENABLE
Cload
DC/DC PWM CONVERTER
RAMP VEE SENSE GATE
7
4
5
6
GND
C1
10nF
R4
12.5m
Q1
IRF530
+5V
COM
Note: capacitor may be needed to slow PWRGD dv/dt if
oscillations are observed when VIN is close to OV.
Application Circuit 14