DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

CDB43L43 Ver la hoja de datos (PDF) - Cirrus Logic

Número de pieza
componentes Descripción
Fabricante
CDB43L43 Datasheet PDF : 36 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
CS43L43
5.0 REGISTER DESCRIPTIONS
5.1 POWER AND MUTING CONTROL (ADDRESS 01H)
7
AMUTE
1
6
SZC1
1
5
SZC0
0
4
POR
1
3
RESERVED
0
2
RESERVED
0
1
PDN
1
0
CP_EN
0
5.1.1 AUTO-MUTE (AMUTE) BIT 7
Default = 1
0 - Disabled
1 - Enabled
Function:
The Digital-to-Analog converter output will mute following the reception of 8192 consecutive audio sam-
ples of static 0 or -1. A single sample of non-static data will release the mute. Detection and muting is
done independently for each channel. The quiescent voltage on the output will be retained. The muting
function is affected, similar to volume control changes, by the Soft and Zero Cross bits in the Power and
Muting Control register.
5.1.2 SOFT RAMP AND ZERO CROSS CONTROL (SZC) BIT 5-6
Default = 10
00 - Immediate Change
01 - Zero Cross Digital and Analog
10 - Ramped Digital and Analog
11 - Reserved
Function:
Immediate Change
When Immediate Change is selected all level changes will take effect immediately in one step.
Zero Cross Digital and Analog
Zero Cross Enable dictates that signal level changes, either by attenuation changes or muting, will occur
on a signal zero crossing to minimize audible artifacts. The requested level change will occur after a
timeout period of 512 sample periods (10.7 ms at 48 kHz sample rate) if the signal does not encounter a
zero crossing. The zero cross function is independently monitored and implemented for each channel.
Ramped Digital and Analog
Soft Ramp allows digital level changes, both muting and attenuation, to be implemented by incrementally
ramping, in 1/8 dB steps, from the current level to the new level at a rate of 1dB per 8 left/right clock pe-
riods. Analog level changes will occur in 1 dB steps on a signal zero crossing. The analog level change
will occur after a timeout period of 512 sample periods (10.7 ms at 48 kHz sample rate) if the signal does
not encounter a zero crossing. The zero cross function is independently monitored and implemented for
each channel.
NOTE: Ramped Digital and Analog is not available in Double-Speed mode.
DS479PP3