Data Sheet AS8168
Parameter
F_cal_sel
F_led_sel
Pulse_lev
Bank01
Sel_def
Description
Select multiplier for
CAL pulse rate
related to
MOP/MON pulse
rate
Select LED pulse
rate [imp/kWh]
Number
of bits
2
3
Central pulse_level 22
value
Select PROM bank 1
0 or 1
Select default or
1
programmed values
Not used
2
Register bits
[28:27] [61:60]
[26:24] [59:57]
[23:2] [56:35]
[1]
[0]
[69:68]
Settings
00 : 8
01 : 16
10 : 32
11 : 64
000 : 100
001 : 200
010 : 400
011 : 800
100 : 1600
101 : 3200
110 : 6400
0 : Bank 0
1 : Bank 1
0 : default
1 : programmed
Value
Default
01
101
0x6A6D4
0
0
00
Total
70
The “Default” values are hard coded on-chip outside the PROM block. Only once the Sel_def bit has been set, are the
PROM parameters selected by the AS8168.
Two PROM banks are defined as ‘Bank 0’ and ‘Bank 1’. This feature allows for a complete reprogramming cycle if necessary.
The required bank is selected with the bit called Bank01.
The calibration of the AS8168 adjusts the specific pulse-level (Pulse_lev), which defines exactly the energy level when a
pulse has to be generated and presented to the output. This pulse-level is used to define a very fast internal pulse rate from
which the external pulse outputs are derived. Therefore, the AS8168 is extremely flexible in defining pulse output rates as
required for a specified kWh meter.
The parameters F_mon_sel, F_cal_sel and F_led_sel are used to define the pulse rates for the pins MOP/MON, CAL and
LED.
The Acreep_sel bit defines the threshold for the current for when no pulses should be transmitted.
Calculations for Calibration
This paragraph describes how to successfully calibrate the AS8168 device. The parameter Pulse_lev is the main parameter
to determine the basic internal (very fast) frequency. This frequency relates to the measured power and is the basis from
which all the output pulse rates namely, MOP/MON, CAL and LED are derived.
Prior to system calibration, the appropriate value for the parameter Pulse_lev must be calculated to produce the required
output pulse rates for MOP/MON, CAL and LED. The calibration exercise must accommodate all system non-idealities that
are present in the meter system.
There are two calibration methods available to find the appropriate value of Pulse_lev, namely:
Revision 1.2, 11-Feb-05
Page 14 of 30