First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
AS1113
Data Sheet - Detailed Description
On the next falling edge of OEN, current is reduced to ILC. With the next rising edge of OEN the current will immedi-
ately increase to normal levels and the detailed error report can be read out entering error-detection mode.
Figure 16. Switching into Low-Current Diagnostic Mode Timing Diagram
OEN
LD
tSU(ERROR)
tGSW(ERROR)
Load Internal all 1s
Test Pattern
(optional)
Low-Current
Diagnosis Mode
tTESTING
tH(L)
CLK
SDI
tGSW(ERROR)
tSW(ERROR)
SDO
TFLAG OFLAG SFLAG
tP1
For detailed timing information see Timing Diagrams on page 9.
Don’t
Care
Re-entering Error
Detection Mode
(see Figure 14)
(see Figure 15)
Normal Operation Current
Shutdown Mode
The AS1113 features a shutdown mode which can be entered via 4 clock pulses during error-detection mode. To
enable the shutdown mode a 0 must be placed at SDI after the rising edge of the 3rd clock pulse.
To disable shutdown mode a 1 must be placed at SDI after the 3rd clock pulse. The shutdown/wakeup information will
be latched through if multiple AS1113 devices are in a chain. At the rising edge of the 4th clock pulse the shutdown bit
will be read out and the AS1113 will shutdown or wakeup.
Note: In shutdown mode the supply current drops down to <10µA.
Figure 17. Shutdown Mode Timing Diagram
OEN
LD
tSU(ERROR)
CLK
SDI
SDO
TFLAG
tP4
OFLAG
SFLAG
1 = Wakeup
0 = Shutdown
1 = Wakeup
0 = Shutdown
tSU(D)
www.austriamicrosystems.com