DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

ADP5022 Ver la hoja de datos (PDF) - Analog Devices

Número de pieza
componentes Descripción
Fabricante
ADP5022 Datasheet PDF : 28 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
ADP5022
LDO SPECIFICATIONS
VDDA = VIN1 = VIN2 = 3.6 V, VIN3 = (VOUT3 + 0.5 V) or 2.3 V, whichever is greater, VIN3 ≤ VIN1, IOUT3 = 10 mA; CIN3 = COUT3 =
1 μF, TJ = −40°C to +125°C, unless otherwise noted.1
Table 3.
Parameter
OPERATING SUPPLY CURRENT2
OUTPUT VOLTAGE ACCURACY
REGULATION
Line Regulation
Load Regulation3
DROPOUT VOLTAGE4
START-UP TIME5
From Shutdown State
CURRENT-LIMIT THRESHOLD6
OUTPUT NOISE
POWER SUPPLY REJECTION RATIO
Symbol
IVIN3-GND
VOUT3
Test Conditions/Comments
IOUT3 = 0 μA
IOUT3 = 10 mA
IOUT3 = 150 mA
100 μA < IOUT3 < 150 mA,
VIN3 = (VOUT3 + 0.5 V) to 5.5 V
Min Typ Max Unit
11 21
μA
16 29
μA
31 43
μA
−2
+2
%
∆VOUT3/∆VIN3 VIN3 = (VOUT3 + 0.5 V) to 5.5 V, IOUT = 1 mA −0.03
+0.03 %/ V
∆VOUT3/∆IOUT3 IOUT3 = 1 mA to 150 mA
0.002 0.0075 %/mA
VDROPOUT
VOUT3 = 3.0 V, IOUT3 = 10 mA
VOUT3 = 3.0 V, IOUT3 = 150 mA
7
mV
110 150 mV
TSTARTUP3-SD
ILIMIT3
OUTNOISE
PSRR
200
160 240 350
10 Hz to 100 kHz, VIN3 = 5 V, VOUT3 = 3.3 V
65
10 Hz to 100 kHz, VIN3= 5 V, VOUT3 = 2.4 V
52
10 Hz to 100 kHz, VIN3 = 5 V, VOUT3 = 1.2 V
40
10 kHz, VIN3 = 5 V, VOUT3 = 3.3 V
60
10 kHz, VIN3 = 5 V, VOUT3 = 2.3 V
66
10 kHz, VIN3 = 5 V, VOUT3 = 1.2 V
70
μs
mA
μV rms
μV rms
μV rms
dB
dB
dB
1 All limits at temperature extremes are guaranteed via correlation using standard statistical quality control.
2 LDO operating supply current is the current drawn from VIN3 to AGND when the LDO is enabled. Whenever any regulator channel is enabled, current is drawn from
VIN1 to AGND. This current is 8 μA typical and is included in the IGND1, IGND2, and IGND1-2 specifications.
3 Based on an end-point calculation using 1 mA and 150 mA loads.
4 Dropout voltage is defined as the input-to-output voltage differential when the input voltage is set to the nominal output voltage. This applies only for output
voltages above 2.3 V.
5 Start-up time is defined as the time between the rising edge of EN3 to VOUT3 being at 90% of its nominal value.
6 Current-limit threshold is defined as the current at which VOUT3 drops to 90% of the specified typical value. For example, the current limit for a 3.0 V output voltage is
defined as the current that causes the output voltage to drop to 90% of 3.0 V or 2.7 V.
Rev. C | Page 5 of 28

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]