ADE7752/ADE7752A
Figure 21 shows the connections of the analog inputs of the
ADE7752 with the power lines in a 3-phase 3-wire delta service.
Note that only two current inputs and two voltage inputs of the
ADE7752 are used in this case. The real power calculated by the
ADE7752 does not depend on the selected channels.
Ra* Cf
Rb*
VR*
PHASE A
Rb*
CT
VAP
IAP
IAN
ANTIALIASING
FILTERS
SOURCE
PHASE B
PHASE C
CT
VN
Rf
Cf
LOAD
Ra* Cf
Rb*
VR*
ANTIALIASING
FILTERS
Rb*
IBP
IBN
VBP
* Ra >> Rf + VR * Rb + VR = Rf
Figure 21. 3-Phase 3-Wire Meter Connection with ADE7752
Figure 22 shows the connections of the analog inputs of the
ADE7752 with the power lines in a 3-phase 4-wire Wye service.
Ra* Cf
Rb*
VR*
Rb*
CT
ANTIALIASING
FILTERS
VAP
IAP
IAN
PHASE A
SOURCE
PHASE B
PHASE C
Ra* Cf
Rb*
VR*
CT
CT
ANTIALIASING
FILTERS
Rb*
IBP
IBN
VBP
Ra* Cf
Rb*
VR*
Rf
VN
ANTIALIASING
FILTERS
Rb*
ICP LOAD
ICN
VCP
CF
* Ra >> Rf + VR; * Rb + VR = Rf
Figure 22. 3-Phase 4-Wire Meter Connection with ADE7752