DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

ACPM-7331-TR1 Ver la hoja de datos (PDF) - Avago Technologies

Número de pieza
componentes Descripción
Fabricante
ACPM-7331-TR1
AVAGO
Avago Technologies AVAGO
ACPM-7331-TR1 Datasheet PDF : 18 Pages
First Prev 11 12 13 14 15 16 17 18
Handling and Storage
ESD (Electrostatic Discharge)
Electrostatic discharge occurs naturally in the environ-
ment. With the increase in voltage potential, the outlet of
neutralization or discharge will be sought. If the acquired
discharge route is through a semiconductor device, de-
structive damage will result.
ESD countermeasure methods should be developed and
used to control potential ESD damage during handling in
a factory environment at each manufacturing site.
MSL (Moisture Sensitivity Level)
Plastic encapsulated surface mount package is sensitive
to damage induced by absorbed moisture and tempera-
ture.
Avago Technologies follows JEDEC Standard J-STD 020B.
Each component and package type is classified for
moisture sensitivity by soaking a known dry package at
various temperatures and relative humidity, and times.
After soak, the components are subjected to three con-
secutive simulated reflows.
The out of bag exposure time maximum limits are deter-
mined by the classification test describe below which cor-
responds to a MSL classification level 6 to 1 according to
the JEDEC standard IPC/JEDEC J-STD-020B and J-STD-033.
ACPM-7331 is MSL3. Thus, according to the J-STD-033
p.11 the maximum Manufacturers Exposure Time (MET)
for this part is 168 hours. After this time period, the part
would need to be removed from the reel, de-taped and
then re-baked. MSL classification reflow temperature for
the ACPM-7331 is targeted at 260°C +0/-5°C. Figure 23
and Table 8 show typical SMT profile for maximum tem-
perature of 260 +0/-5°C.
Table 6. ESD Classification
Pin # Name
1
Vcc1
2
RF In
3
Vmode1
4
Vmode0
5
Ven
6
GND
7
GND
8
RF Out
9
GND
10
Vcc2
Description
Supply Voltage
RF Input
Control Voltage
Control Voltage
Enable Voltage
Ground
Ground
RF Output
Ground
Supply Voltage
HBM
± 2000V
± 2000V
± 2000V
± 2000V
± 2000V
± 2000V
± 2000V
± 2000V
± 2000V
± 2000V
Note :
1. Module products should be considered extremely ESD sensitive.
CDM
± 200V
± 200V
± 200V
± 200V
± 200V
± 200V
± 200V
± 200V
± 200V
± 200V
Classification
Class 2
Class 2
Class 2
Class 2
Class 2
Class 2
Class 2
Class 2
Class 2
Class 2
Table 7. Moisture Classification Level and Floor Life
MSL Floor Life (out of bag) at factory ambient
Level =< 30°C/60% RH or as stated
1 Unlimited at =< 30oC/85% RH
2 1 year
2a 4 weeks
3 168 hours
4 72 hours
5 48 hours
5a 24 hours
6 Mandatory bake before use. After bake, must be reflowed within the time limit specified on the label
Note :
1. The MSL Level is marked on the MSL Label on each shipping bag.
14