A67P8318/A67P7336
ICC Operating Condition and Maximum Limits
Symbol
Parameter
Max.
Unit
-2.6 -2.8 -3.2 -3.5 -3.8 -4.2
Conditions
ICC
Power Supply
Current : Operating
TBD TBD TBD TBD TBD TBD
mA
Device selected; All inputs ≤ VIL
or ≥ VIH; Cycle time ≥ tKC (MIN);
VCC = MAX; Outputs open
ISB
Standby
Device deselected; VCC = MAX;
TBD TBD TBD TBD TBD TBD mA All inputs ≤ VSS+0.2 or ≥ VCC-
0.2; Cycle time ≥ tKC (MIN)
ISB1
Standby
Device deselected; VCC = MAX;
TBD TBD TBD TBD TBD TBD mA All inputs ≤VSS+0.2 or ≥ VCC-
0.2; All inputs static; CLK
frequency=0
ZZ ≤ 0.2V
ISB2 Standby
Device deselected; VCC = MAX;
TBD TBD TBD TBD TBD TBD mA All inputs ≤ VIL; or ≥ VIH;
All inputs static;
CLK frequency=MAX
ZZ ≥ VCC-0.2V
ISB2Z SLEEP Mode
TBD TBD TBD TBD TBD TBD mA ZZ ≥ VIH
PRELIMINARY (July, 2005, Version 0.0)
11