3209 AND 3210
MICROPOWER,
ULTRA-SENSITIVE
HALL-EFFECT SWITCHES
TYPICAL OPERATING CHARACTERISTICS
as a function of temperature
SWITCH POINTS
60
40
BOPS
20
BRPS
0
VDD = 2.75 V
-20
BRPN
-40
BOPN
-60
-50
-25
0
25
50
AMBIENT TEMPERATURE IN °C
75
100
Dwg. GH-027-2
A3209-- SUPPLY CURRENT
220
200
VDD = 3.5 V
180
VDD = 3 V
160
140
VDD = 2.5 V
120
-50
-25
0
25
50
AMBIENT TEMPERATURE IN °C
75
100
Dwg. GH-028-7
A3210-- SUPPLY CURRENT
16
14
VDD = 3.5 V
12
VDD = 2.5 V
10
VDD = 3 V
8.0
6.0
-50
-25
0
25
50
AMBIENT TEMPERATURE IN °C
75
100
Dwg. GH-028-6
115 Northeast Cutoff, Box 15036
4
Worcester, Massachusetts 01615-0036 (508) 853-5000