DC Electrical Characteristics
For ACT Family Devices over Operating Temperature Range (unless otherwise specified).
Symbol
VIH
Parameter
Minimum HIGH
Level Input Voltage
VCC (V) Conditions
4.5 VOUT = 0.1V
5.5 or VCC – 0.1V
TA = +25°C,
CL = 50pF TA = –40°C to +85°C
Typ.
Guaranteed Limits Units
1.5 2.0
2.0
V
1.5 2.0
2.0
VIL
Maximum LOW
4.5 VOUT = 0.1V
1.5 0.8
0.8
V
Level Input Voltage
5.5 or VCC – 0.1V
1.5 0.8
0.8
VOH
Minimum HIGH
4.5 IOUT = –50 µA
4.49 4.4
4.4
V
Level Output Voltage 5.5
5.49 5.4
5.4
4.5 VIN = VIL/VIH,
3.86
3.76
V
5.5 IOH = –8 mA(1)
4.86
4.76
VOL
Maximum LOW
4.5 IOUT = 50µA
0.001 0.1
0.1
V
Level Output Voltage 5.5
0.001 0.1
0.1
4.5 VIN = VIL/VIH,
5.5 IOH = +8mA(1)
0.36
0.44
V
0.36
0.44
IOLD Minimum Dynamic
Output Current
5.5 VOLD = 1.65V
32.0
mA
IOHD
Minimum Dynamic
Output Current
5.5 VOHD = 3.85V
–32.0
mA
IIN
Maximum Input
Leakage Current
5.5 VI = VCC, GND
±0.1
±1.0
µA
ICC
Supply Current
Quiescent
5.5 VIN = VCC, GND
8.0
80
µA
ICCT
Maximum ICC/Input
5.5 VIN = VCC – 2.1V
0.6
1.5
mA
Notes:
1. All outputs loaded; thresholds on input associated with input under test.
2. Test Load 50pF, 500Ω to Ground.
AC Electrical Characteristics
Symbol
Parameter
fMAXI
Interlaced fMAX
(HMAX/2 is ODD)
fMAX
Non-Interlaced fMAX
(HMAX/2 is EVEN)
tPLH1, tPHL1 Clock to Any Output
tPLH2, tPHL2 Clock to ODDEVEN
(Scan Mode)
tPLH3 Load to Outputs
VCC (V)
5.0
5.0
5.0
5.0
5.0
TA = +25°C,
CL = 50pF
Min. Typ. Max.
170 190
TA = –40°C to +85°C,
CL = 50pF
Min.
Max.
150
Units
MHz
190 220
175
MHz
4.0 13.0 15.5
3.5
4.5 15.0 17.0
3.5
18.5
ns
20.5
ns
4.0 11.5 16.0
3.0
19.5
ns
©1988 Fairchild Semiconductor Corporation
74ACT715, 74ACT715-R Rev. 1.3
13