2N6400 thru 2N6405
ELECTRICAL CHARACTERISTICS (TC = 25°C unless otherwise noted.)
Characteristic
* Peak Forward or Reverse Blocking Current
(VAK = Rated VDRM or VRRM, Gate Open)
TJ = 25°C
TJ = 125°C
* Peak On–State Voltage
(ITM = 32 A Peak, Pulse Width ≤ 1 ms, Duty Cycle ≤ 2%)
* Gate Trigger Current (Continuous dc)
(VD = 12 Vdc, RL = 50 Ohms)
* Gate Trigger Voltage (Continuous dc)
(VD = 12 Vdc, RL = 50 Ohms)
(VD = Rated VDRM, RL = 50 Ohms)
TC = 25°C
TC = –40°C
TC = +125°C
* Holding Current
(VD = 12 Vdc, Gate Open)
TC = 25°C
*TC = –40°C
Turn-On Time
(ITM = 16 A, IGT = 40 mAdc, VD = Rated VDRM)
Turn-Off Time
(ITM = 16 A, IR = 16 A, VD = Rated VDRM)
TC = 25°C
TJ = +125°C
Critical Rate–of–Rise of Off-State Voltage
(VD = Rated VDRM, Exponential Waveform)
TJ = +125°C
*Indicates JEDEC Registered Data.
Symbol
IDRM, IRRM
VTM
IGT
VGT
IH
tgt
tq
dv/dt
Min
Typ
Max
Unit
—
—
10
µA
—
—
2
mA
—
—
1.7
Volts
—
5
30
mA
Volts
—
0.7
1.5
—
—
2.5
0.2
—
—
—
6
40
mA
—
—
60
—
1
—
µs
µs
—
15
—
—
35
—
—
50
—
V/µs
FIGURE 1 — AVERAGE CURRENT DERATING
128
124
α
120
α = CONDUCTION ANGLE
116
112
dc
108
104
100
0
α = 30°
180°
60° 90° 120°
1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10
IT(AV), AVERAGE ON-STATE FORWARD CURRENT (AMPS)
FIGURE 2 — MAXIMUM ON-STATE POWER DISSIPATION
16
14
TJ ≈ 125°C
12
10
α = 30°
8.0
180°
90° 120°
dc
60°
6.0
4.0
2.0
α
α = CONDUCTION ANGLE
0
0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10
IT(AV), AVERAGE ON-STATE FORWARD CURRENT (AMPS)
2
Motorola Thyristor Device Data