DC and AC characteristics
M27C1001
TA = 0 to 70°C, –40 to 85°C or –40 to 125°C; VCC = 5V ± 5% or 5V ± 10%; VPP = VCC
Table 10. Read Mode AC Characteristics (1)
M27C1001
Symbol Alt
Parameter
Test
Condition
-80
-90
-10
-12/-15/
-20/-25
Unit
Min Max Min Max Min Max Min Max
tAVQV
tELQV
tACC
Address Valid to
Output Valid
E = VIL, G =
VIL
tCE
Chip Enable Low
to Output Valid
G = VIL
tGLQV
Output Enable
tOE Low to Output
Valid
E = VIL
tEHQZ (2)
tDF
Chip Enable High
to Output Hi-Z
G = VIL
tGHQZ
(2)
Output Enable
tDF High to Output
Hi-Z
E = VIL
tAXQX
tOH
Address
Transition to
Output Transition
E = VIL, G =
VIL
80
90
100
120 ns
80
90
100
120 ns
40
45
50
60 ns
0 30 0 30 0 30 0 40 ns
0 30 0 30 0 30 0 40 ns
0
0
0
0
ns
1. VCC must be applied simultaneously with or before VPP and removed simultaneously or after VPP.
2. Sampled only, not 100% tested.
Figure 8. Read Mode AC Waveforms
A0-A16
E
G
Q0-Q7
VALID
tAVQV
tGLQV
tELQV
tAXQX
VALID
tEHQZ
tGHQZ
Hi-Z
AI00713B
16/24