VN750-E / VN750S-E / VN750PT-E / VN750B5-E
Figure 27. SO-8 Maximum turn off current versus load inductance
ILMAX (A)
100
10
1
0.1
1
A = Single Pulse at TJstart=150ºC
B= Repetitive pulse at TJstart=100ºC
C= Repetitive Pulse at TJstart=125ºC
Conditions:
VCC=13.5V
VIN, IL
Demagnetization
A
B
C
10
100
L (mH )
Values are generated with RL=0Ω
In case of repetitive pulses, Tjstart (at beginning of
each demagnetization) of every pulse must not
exceed the temperature specified above for
curves B and C.
Demagnetization
Demagnetization
t
14/31