Overvoltage Protection Controllers with
Status FLAG
Table 1. MOSFET Suggestions
PART
Si9936DY
Si5904DC
Si1426DH
FDC6305N
FDS8926A
FDG315N
IRF7752
IRF7303
IRF7607
CONFIGURATION/
PACKAGE
Dual/SO8
Dual/1206-8
Single/SC70-6
Dual/SSOT-6
Dual/SO8
Single/SC70-6
Dual/TSSOP-8
Dual/SO8
Single/Micro-8
VDS MAX (V)
30
30
30
20
30
30
30
30
20
RON AT 4.5V
(m)
80
143
115
80
20
160
36
80
30
MANUFACTURER
Vishay Siliconix
www.vishay.com
402-563-6866
Fairchild Semiconductor
www.fairchildsemi.com
207-775-8100
International Rectifier
www.irf.com
310-322-3331
Human Body Model
Figure 8 shows the Human Body Model and Figure 9
shows the current waveform it generates when dis-
charged into a low impedance. This model consists of
a 100pF capacitor charged to the ESD voltage of inter-
est, which is then discharged into the device through a
1.5kresistor.
IEC 1000-4-2
Since January 1996, all equipment manufactured and/or
sold in the European community has been required to
meet the stringent IEC 1000-4-2 specification. The IEC
1000-4-2 standard covers ESD testing and performance
of finished equipment; it does not specifically refer to
integrated circuits. The MAX4838MAX4841 help users
design equipment that meets Level 3 of IEC 1000-4-2,
without additional ESD-protection components.
The main difference between tests done using the
Human Body Model and IEC 1000-4-2 is higher peak
current in IEC 1000-4-2. Because series resistance is
lower in the IEC 1000-4-2 ESD test model (Figure 10),
the ESD-withstand voltage measured to this standard is
generally lower than that measured using the Human
Body Model. Figure 11 shows the current waveform for
the ±8kV IEC 1000-4-2 Level 4 ESD Contact Discharge
test. The Air-Gap test involves approaching the device
with a charger probe. The Contact Discharge method
connects the probe to the device before the probe is
energized.
RC
1M
RD
1.5k
CHARGE-CURRENT-
LIMIT RESISTOR
DISCHARGE
RESISTANCE
HIGH-
VOLTAGE
DC
SOURCE
Cs
100pF
STORAGE
CAPACITOR
Figure 8. Human Body ESD Test Model
DEVICE
UNDER
TEST
IP 100%
90%
AMPERES
36.8%
10%
0
0 tRL
Ir
PEAK-TO-PEAK RINGING
(NOT DRAWN TO SCALE)
TIME
tDL
CURRENT WAVEFORM
Figure 9. Human Body Model Current Waveform
8 _______________________________________________________________________________________