18-Port GPIO with LED Intensity Control,
Interrupt, and Hot-Insertion Protection
Table 5. Ports Configuration Registers
REGISTER
ADDRESS
R/W CODE
REGISTER DATA
(hex)
D7
D6
D5
D4
D3
D2
D1
D0
Ports configuration P7–P0
(1 = input, 0 = output)
0
0x06
OP7 OP6 OP5 OP4 OP3 OP2 OP1 OP0
Read back ports configuration P7–P0
1
Ports configuration P15–P8
(1 = input, 0 = output)
0
0x07 OP15 OP14 OP13 OP12 OP11 OP10 OP9 OP8
Read back ports configuration P15–P8 1
Table 6. Input Ports Registers
REGISTER
Read input ports P7–P0
Read input ports P15–P8
ADDRESS
R/W CODE
REGISTER DATA
(hex)
D7
D6
D5
D4
D3
D2
D1
D0
1
0x00
IP7 IP6 IP5 IP4 IP3 IP2 IP1 IP0
1
0x01
IP15 IP14 IP13 IP12 IP11 IP10 IP9 IP8
Table 7. Blink Logic
BLINK ENABLE
FLAG E
BLINK FLIP
FLAG B
0
X
0
0
1
1
1
BLINK INPUT
PIN
X
0
1
0
1
BLINK FLIP FLAG
EXOR
BLINK FUNCTION
BLINK INPUT PIN
X
Disabled
0
1
Enabled
1
0
OUTPUT REGISTERS USED
Blink phase 0 registers
Blink phase 0 registers
Blink phase 1 registers
Blink phase 1 registers
Blink phase 0 registers
Reading a blink phase register reads the value stored
in the register, not the actual port condition. The port
output itself may or may not be at a valid logic level,
depending on the external load connected.
The 17th output, O16, is controlled through 2 bits in the
configuration register, which provide the same static or
blink control as the other 16 output ports.
PWM Intensity Control
The MAX7314 includes an internal oscillator, nominally
32kHz, to generate PWM timing for LED intensity con-
trol or other applications such as PWM trim DACs.
PWM can be disabled entirely for all the outputs. In this
case, all outputs are static and the MAX7314 operating
current is lowest because the internal PWM oscillator is
turned off.
The MAX7314 can be configured to provide any combi-
nation of PWM outputs and glitch-free logic outputs.
Each PWM output has an individual 4-bit intensity con-
trol (Table 14). When all outputs are to be used with the
same PWM setting, the outputs can be controlled
together instead using the global intensity control
(Table 13). Table 10 shows how to set up the MAX7314
to suit a particular application.
PWM Timing
The PWM control uses a 240-step PWM period, divided
into 15 master intensity timeslots. Each master intensity
timeslot is divided further into 16 PWM cycles (Figure 12).
The master intensity operates as a gate, allowing the indi-
vidual output settings to be enabled from 1 to 15 timeslots
per PWM period (Figures 13, 14, 15) (Table 13).