DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MAX14578E Ver la hoja de datos (PDF) - Maxim Integrated

Número de pieza
componentes Descripción
Fabricante
MAX14578E
MaximIC
Maxim Integrated MaximIC
MAX14578E Datasheet PDF : 23 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
MAX14578E/MAX14578AE
USB Battery Charger Detectors
Table 1. Register Map
ADDRESS NAME
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
0x00 DEVICE ID
VENDOR_ID
0x01
CONTROL
1
INTPOL
INTEN USBSWC CP_ENA LOW_POW
0x02 INTERRUPT
CHG_TYP
VBCOMP DBCHG
0x03
CONTROL
2
DCD_EN DB_EXIT DB_IDLE SUS_LOW
CE_FRC
BIT 2
BIT 1
CHIP_REV
BIT 0
DCHK CHG_TYP_M USB_CHGDET
DCD_T CHGRUN
RFU
CE
0x04
CONTROL
3
RFU
RFU
RFU CDP_DET USB_CPL SFOUT_EN SFOUTASRT DCD_EXIT
Table 2. Detailed Register Map
FIELD NAME
READ/WRITE
DEVICE ID (I2C ADDRESS = 0x00)
VENDOR_ID
Read Only
CHIP_REV
Read Only
CONTROL 1 (I2C ADDRESS = 0x01)
BIT
[7:4]
[3:0]
INTPOL
Read/Write
7
INTEN
Read/Write
6
USBSWC
CP_ENA
Read/Write
5
Read/Write
4
LOW_POW
Read/Write
3
DCHK
Read/Write
2
CHG_TYP_M
Read/Write
1
Maxim Integrated
DEFAULT
DESCRIPTION
0010
0001
Vendor Identification
Chip Revision
Interrupt Polarity
0
0 = Active low
1 = Active high
Interrupt Enable. If interrupt is disabled, pending interrupts
are not cleared and the INT pin deasserts. INTEN is a
0
global setting to mask all interrupts.
0 = Interrupt disabled
1 = Interrupt enabled
Opens/Closes USB Switch
0
0 = Switch open
1 = Switch closed
Charge-Pump Enable
0
0 = Charge pump disabled
1 = Charge pump enabled
Low-Power Mode
0 = Low-power mode disabled; oscillator/bandgap always on
1
1 = Low-power mode enabled; oscillator/bandgap turned
off under the following conditions: no VBUS, USBSWC = 0,
and CP_ENA = 0
Charger-Type Source-Detection Time
0
0 = DCHK, tDP_SRC_ON = 40ms
1 = DCHK, tDP_SRC_ON = 625ms
Charger-Type Manual-Detection Enable. Set CHG_TYP_M
to 1 to force the internal logic to open the USB switches
0
and perform a charger-type detection. After the detection
state matching completes, this bit resets to 0.
0 = Charger detection disabled
1 = Force a manual charge detection
  11

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]