Data Sheet AS8218 / AS8228
LED Output Timing
The pulses on the LED output indicate the amount of energy that has been consumed over a certain period of
time. Each pulse has an equivalent that can be set in the SREG/mconst register exactly. The unit is impulses
per kWh (i/kWh).
This output may be used for calibration.
The polarity of the LED pulses may be selected via the ledpol bit in the SREG/Select Register for either
positive or negative going pulses.
Timing Diagram
Timing Parameters
Parameter
Pulse width
Symbol Min
Typ
Max Unit Notes
t1
80
ms 50% duty cycle is enabled when the LED
period is less than 160ms. For mconst=0,
t1 will be 17.9µs.
Register Interface to MCU
One register block contains the data for the Meter Data Register (MDR) and the Settings Register (SREG),
hence only one interface to the MCU is required.
Meter Data Register (MDR)
The meter data register is updated after ‘nsamp’ samples. Then an interrupt is issued to the MCU, which may
take the energy data and process them further on. When an interrupt is generated the ‘ack’ bit in the
SREG/Status register is set. If the MCU takes the data, it has to reset the ‘ack’ bit.
If the ‘ack’ bit has not been reset by the MCU when a new set of data is ready, the previous np value will be
added to the new one.
In any case the dai flag in the SREG/Status register must be reset in order to clear the interrupt.