SLx 24C64
6.2 Current Address Read
The EEPROM content is read without setting an EEPROM address, in this case the
current content of the address counter will be used (e.g. to continue a previous read
operation after the Master has served an interrupt).
Transmission of CSR
Transmission of
EEPROM Data
STOP Condition from
Master
For a current address read the master generates a START
condition, which is followed by the command byte CSR (Chip
Select Read). The receipt of the CSR-byte is acknowledged by
the EEPROM with a low on the SDA line.
During the next eight clock pulses the EEPROM transmits the
data byte and increments the internal address counter by one
byte.
During the following clock cycle the masters releases the bus
and then transmits the STOP condition.
S
T
S
Bus Activity A Command Byte
T
Master
R
CSR
O
T
P
SDA Line S
1
P
Bus Activity
EEPROM
A Data Byte
C
K
IED02132