14.Reliability
Content of Reliability Test (wide temperature, -20℃~70℃)
Environmental Test
Test Item
High Temperature
storage
Low Temperature
storage
High Temperature
Operation
Low Temperature
Operation
High Temperature/
Humidity Operation
Thermal shock
resistance
Content of Test
Test Condition
Endurance test applying the high storage
80℃
temperature for a long time.
200hrs
Endurance test applying the high storage
-30℃
temperature for a long time.
200hrs
Endurance test applying the electric stress
(Voltage & Current) and the thermal stress to the
element for a long time.
Endurance test applying the electric stress under
70℃
200hrs
-20℃
low temperature for a long time.
200hrs
The module should be allowed to stand at 60
℃,90%RH max
For 96hrs under no-load condition excluding the 60℃,90%RH
polarizer,
96hrs
Then taking it out and drying it at normal
temperature.
The sample should be allowed stand the following
10 cycles of
operation
-20℃ 25℃ 70℃
-20℃/70℃
10 cycles
Note
2
1,2
——
1
1,2
——
Vibration test
30min 5min 30min
1 cycle
Endurance test applying the vibration during
transportation and using.
Total fixed
amplitude : 1.5mm
Vibration
Frequency : 10~55Hz
One cycle 60 seconds
3
to 3 directions of
X,Y,Z for
Each 15 minutes
Static electricity test
Endurance test applying the electric stress to the
terminal.
VS=800V,RS=1.5kΩ
CS=100pF
1 time
——
Note1: No dew condensation to be observed.
Note2: The function test shall be conducted after 4 hours storage at the normal
Temperature and humidity after remove from the test chamber.
Note3: Vibration test will be conducted to the product itself without putting it in a container.
第 19 頁,共 28 頁