Continued from preceding page.
Symbol R/W
LC587008, 587006, 587004
Function
Status register 3 (STS3)
Status register 3 is a 4-bit register that is used to confirm the HALT and STOP clear conditions.
Initialization
value at reset
STS3
R/O
SCF0: Set to 1 if there was a signal change on the INT pin.
SCF1: Set to 1 if there was a signal change on the K port.
SCF2: Set to 1 if any of the flags in STS4 is set.
SCF3: Set to 1 if there was a signal change on the S port.
Note: SCF0 is used when enabled by an SF2-1 instruction.
SCF1 and SCF3 are used when enabled by an SSW instruction.
Status register 4 (STS4)
Status register 4 is a 4-bit register that is used to confirm the HALT and STOP clear conditions.
STS4
R/O
SCF4: Divider overflow
SCF5: Timer 1 underflow
SCF6: Timer 2 underflow
SCF7: Serial counter overflow or signal change on SO4
Status register 5 (STS5)
Status register 5 is a 4-bit register whose bits are used as shown below.
STS5
R/O
Bits 0 and 1: These bits are always 0 and cannot be used.
INTIN:
Reflects in the input data on the INT pin.
STBF:
Strobe flag for the segment port
(Set to 1 for 00 to 0F and to 0 for 10 to 1E.)
00H
00H
00H