STPS0520Z
THERMAL RESISTANCE
Symbol
Rth (j-a) Junction to ambient
Parameter
(*) Mounted on epoxy board with recommended Pad Layout.
(**) Mounted on epoxy board with 50mm2 copper area.
STATIC ELECTRICAL CHARACTERISTICS
Symbol
Parameter
Tests conditions
IR * Reverse leakage current
Tj = 25°C
VR = 10 V
Tj = 100°C
Tj = 25°C
VR = VRRM
Tj = 100°C
VF ** Forward voltage drop
Tj = 25°C
IF = 0.1 A
Tj = 100°C
Tj = 25°C
IF = 0.5 A
Tj=100°C
Pulse test : * tp = 5 ms, δ < 2%
** tp = 380 µs, δ < 2%
To evaluate the maximum conduction losses use the following equation :
P = 0.23 x IF(AV) + 0.18 x IF2(RMS)
Value
430 (*)
210 (**)
Unit
°C/W
Value
STPS0520Z Unit
typ. max.
60
µA
2.5
5
mA
150 µA
4.3
8
mA
0.3
V
0.18 0.22
0.385
0.29 0.32
2/5