Example:
Remote terminal will transmit and buffer three MIL-STD-1553 transmit commands of various word lengths to
Subaddress 16.
MIL-STD-1553 Bus Activity:
CMD WORD #1 SW DW0 DW1 DW2 DW3
SA= 16
T/R=1
WC= 4
CMD WORD #2 SW DW0 DW1
SA= 16
T/R=1
WC= 2
CMD WORD #3 SW DW0 DW1 DW2 DW3
SA= 16
T/R=1
WC= 4
Transmit Subaddress 16;
data pointer at 03F0
(hex). (Initial condition)
After message #1,
4 data words.
03F0 (hex)
03F0 (hex)
0830 (hex)
0434 (hex)
INDEX= 0000 10
ADDRESS= 00 0011 0000
INDEX= 0000 01
ADDRESS= 00 0011 0100
After message #2,
2 data words.
After message #3,
4 data words.
03F0 (hex) 0036 (hex)
INDEX= 0000 00
ADDRESS= 00 0011 0110
03F0 (hex) 0036 (hex)
INDEX= 0000 00
ADDRESS= 00 0011 0110
Figure 7. RTR Message Handling
0830 (hex)
0434 (hex)
0036 (hex)
030436(h(hexe)x)
DATA WORD 0
DATA WORD 1
DATA WORD 2
DATA WORD 3
DATA WORD 0
DATA WORD 1
DATA WORD 0
DATA WORD 1
DATA WORD 2
DATA WORD 3
Note:
The example is valid only if message structure is known in advance.
Figure 8. Memory Storage Subaddress 16
030 (hex)
031 (hex)
032 (hex)
033 (hex)
034 (hex)
035 (hex)
036 (hex)
037 (hex)
038 (hex)
039 (hex)
RTR-13