Performance at 28VDC & 25ºC (continued)
Parameter
Symbol
Min
IMD Variation – 100 kHz to 25 MHz tone spacing
2nd Harmonic at 60W Pout(single tone)
3rd Harmonic at 60W Pout(single tone)
Group (Signal) Delay
τd
Transmission Phase Flatness
Drain Efficiency at 12.5W W-CDMA Output
η
20
W-CDMA ACPR at 4.8W Pout (single channel) (1)
W-CDMA ACPR at 7.6W Pout (single channel) (1)
W-CDMA ACPR at 12.0W Pout (single channel) (1)
W-CDMA ACPR at 2.4W Pout (2 channels at 10MHz) (1)
W-CDMA ACPR at 3.8W Pout (2 channels at 10MHz) (1)
W-CDMA ACPR at 6.0W Pout (2 channels at 10MHz) (1)
W-CDMA Alt 1 at 2.4W Pout (2 channels at 10MHz) (1)
W-CDMA Alt 1 at 3.8W Pout (2 channels at 10MHz) (1)
W-CDMA Alt 1 at 6.0W Pout (2 channels at 10MHz) (1)
Performance at 28VDC Over Temperature
Parameter
Symbol
Min
Power Output at 1 dB Compression (single tone)
P-1
Gain Variation over frequency at 12W Output (two tone)
G
Input Return Loss (50 Ref) at 12W Output (two tone)
IRL
Drain Efficiency at 60W PEP (two tone)
η
3rd Order IMD Product (2 tone at 60W PEP;1 MHz spacing)
Group (Signal) Delay
τd
Transmission Phase Flatness
Nom
1.0
1.8
0.6
22
-46
-44
-39
-45
-44
-42
-43
-39
-37
Max
2.0
1.0
Units
dB
dBc
dBc
ns
degrees
%
dBc
dBc
dBc
dBc
dBc
dBc
dBc
dBc
dBc
Nom
-29
1.8
0.6
Max
-27
1.0
Units
W
dB
dB
%
dBc
ns
degrees
Notes:
(1) W-CDMA test waveform used is 3GPP Test Model 1, 64DHCP, 10.5dB Peak to Average ratio.
This GR-version QuikPAC module has an internally regulated gate voltage that is preset at the factory. A voltage of
+12VDC (±1V) should be applied to the gate lead (pin 1). No further adjustment is required. The gate voltage is thermally
compensated for operation over the temperature range listed in the data sheet. Although the module will operate with
lower voltages applied, the internal regulator is not functioning and the specified performance may not be achieved.
Gate voltage must be applied coincident with or after application of the drain voltage to prevent potentially destructive
oscillations. Bias voltages should never be applied to a module unless it is terminated on both input and output.
The quiescent current set during manufacture will be within the range specified in the Performance section (nominal
±10%) and is selected to balance IMD, input return loss, and efficiency. This setting is suitable for most applications.
Modules with different optimization profiles are available by special order.
Internal RF decoupling is included on all bias leads. No additional bypass elements are required, however some
applications may require energy storage on the drain leads to accommodate time-varying waveforms.
The RF leads are internally protected against DC voltages up to 100V. Care should be taken to avoid video transients that
may damage the active devices.