NJU6475B
(g) Function Set
RS R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0
Code 0 0 0
01*
*
*
* PD *= Don't Care
Function set instruction which sets the interface data length and power down is executed, when the code
"1" is written into DB5 and (PD) is written into DB0, as shown below.
When the power down mode is set, the display turns off automatically. Afterward, when the power down
mode is reset, the display is off continuously.
The display appears by the display on instruction.
PD
Function
1 Power down mode off (Normal operation)
0 Power down mode on (the display goes to off automatically.)
(h) Set Electronic Volume Register
RS
Code 0
R/W
0
DB7 DB6 DB5 DB4
0
1*
*
Higher order bit
DB3 DB2 DB1 DB0
C3
C2
C1
C0
Lower order bit
*= Don't Care
Contrast Control instruction which adjusts the contrast of LCD, is executed when the code "1"
into DB6 and the codes of C0 to C3 are written into DB0 to DB3 as shown below.
The contrast of LCD can be adjusted one of 16 voltage stage by setting 4 bit register.
Set the binary code "0000" when contrast control unused.
is written
C3
C2
C1
C0
0
0
0
0
:
:
1
1
1
1
VLCD
low
VLCD = VDD - V5
high