GaAs SP4T Absorptive Switch, DC - 3 GHz
Electrical Specifications4,5 (From –55°C to +85°C)
Parameter
Test Conditions
Frequency
Units
Min
Insertion Loss
Isolation
VSWR
VSWR
Trise, Tfall
—
—
RFC, RF1 - RF4 (On)
RF1 - RF4 (Off)
10% to 90%
DC - 0.5 GHz
DC - 1.0 GHz
DC - 2.0 GHz
DC - 3.0 GHz
DC - 0.5 GHz
DC - 1.0 GHz
DC - 2.0 GHz
DC - 3.0 GHz
DC - 0.5 GHz
DC - 1.0 GHz
DC - 2.0 GHz
DC - 3.0 GHz
DC - 0.5 GHz
DC - 1.0 GHz
DC - 2.0 GHz
DC - 3.0 GHz
—
dB
—
dB
—
dB
—
dB
—
dB
50
dB
40
dB
35
dB
30
Ratio
—
Ratio
—
Ratio
—
Ratio
—
Ratio
—
Ratio
—
Ratio
—
Ratio
—
ns
—
Ton, Toff
50% Control to 90% / 10% RF
—
ns
—
Transients
In-Band (peak-peak)
—
mV
—
1 dB Compression
Input Power
0.05 GHz
dBm
—
0.5 GHz to 3 GHz
dBm
—
IP3
Two-Tone Input Power up to +5 dBm
0.05 GHz
dBm
—
0.5 GHz to 3 GHz
dBm
—
IP2
Two-Tone Input Power up to +5 dBm
0.05 GHz
dBm
—
0.5 GHz to 3 GHz
dBm
—
Vcc
—
—
V
4.5
Vee
—
—
V
-8.0
Icc
Vcc = 4.5 to 5.5 V
—
Vctl = 0 to 0.8V, or Vcc –2.1V to Vcc
Iee
Vee = -5.0V to -8.0V
—
mA
—
mA
—
Vctl
Vctl
Input Leakage
Current (Low)
Input Leakage
Current (High)
Logic 0 (TTL)
Logic 1 (TTL)
0 to 0.8V
2.0 to 5.0V
—
V
0.0
—
V
2.0
—
µA
—
—
µA
—
4. All specifications apply when operated with bias voltages of +5V for Vcc and –5V for Vee.
5. When DC blocks are used, a 10K ohm return to GND is required on the RFC port.
SW-314
V5
Typ
Max
—
1.3
—
1.4
—
1.6
—
1.8
—
—
—
—
—
—
—
—
—
1.6:1
—
1.6:1
—
1.6:1
—
1.8:1
—
1.3:1
—
1.5:1
—
1.9:1
—
2.4:1
7
—
25
—
20
—
+20
—
+27
—
+35
—
+46
—
+45
—
+60
—
5.0
5.5
—
-5.0
0.2
4.0
0.1
1.0
—
0.8
—
5.0
—
1.0
—
1.0
M/A-COM Inc. and its affiliates reserve the right to make changes to the product(s)
or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
North America: Tel. (800) 366-2266
2