Philips Semiconductors
HF amplifier modules
Product specification
BGY148A; BGY148B
SOLDERING
The indicated temperatures are those at the solder
interfaces.
Advised solder types are types with a liquidus less than or
equal to 210 °C.
Solder dots or solder prints must be large enough to wet
the contact areas.
Soldering can be carried out using a conveyor oven, a hot
air oven, an infrared oven or a combination of these ovens.
A double reflow process is permitted.
Hand soldering must be avoided because the soldering
iron tip can exceed the maximum permitted temperature of
250 °C and damage the module.
The maximum allowed temperature is 250 °C for
5 seconds.
The maximum ramp-up is 10 °C per second.
The maximum cool-down is 5 °C per second.
Cleaning
The following fluids may be used for cleaning:
• Alcohol
• Bio-Act (Terpene Hydrocarbon)
• Acetone.
Ultrasonic cleaning should not be used since this can
cause serious damage to the product.
300
handbook, halfpage
T
(°C)
200
MGM159
100
0
0
1
2
3
4 t (min) 5
Fig.17 Recommended reflow temperature profile.
1998 May 13