Recommended Operating Conditions:
Parameter
Symbol
Supply Voltage
VCC
Operating Temperature
TA
Test Conditions
Min Typ Max Unit
4.75 – 5.25 V
0
– 70 °C
Electrical Characteristics: (Note 3, Note 4)
Parameter
Symbol
Test Conditions
Min Typ Max Unit
Logical “1” Input Voltage
Logical “0” Input Voltage
Logical “1” Output Voltage
Logical “0” Output Voltage
Logical “1” Input Current
Logical “0” Input Current
VIH
VIL
VOH
VOL
IIH
IIL
VCC = Min
VCC = Min
VCC = Min, IOUT = –200µA, RBO
VCC = Min, IOUT = 8mA, RBO
VCC = Max, Except BI VIN = 2.4V
VIN = 5.5V
VCC = Max, VIN = 0.4V Except BI
BI
2.0 – – V
– – 0.8 V
2.4 3.7 – V
– 0.13 0.4 V
–
2 15 µA
–
4 400 µA
– –300 –600 µA
– –1.2 –2.0 mA
Power Supply Current
Input Diode Clamp Voltage
Segment Outputs “ON” Current Ratio
ICC VCC = Max, RP = 2.2k, All Inputs = 0V – 27 43 mA
VCD VCC = Max, TA = +25°C, IIN = –12mA
– –0.9 –1.5 V
IO All Outputs = 50V,
IOUTb = Ref
Outputs a, f, g 0.84 0.93 1.02
Output c
1.12 1.25 1.38
Output d
0.90 1.00 1.10
Output e
0.99 1.10 1.21
Output b “ON” Current
Output Saturation Voltage
Output Leakage Current
Output Breakdown Voltage
Propagation Delays
BCD Input to Segment Output
BI to Segment Output
Ib ON
VSAT
ICEX
VBR
tpd
VCC = 5V,
VOUTb = 50V,
All Other Outputs ≥ 5V,
TA = +25°C
RP = 18.1k
RP = 7.03k
RP = 3.40k
RP = 2.20k
VCC = Min, RP = 1k ±5%,
IOUTb = 2mA, Note 5
VOUT = 75V, BI = 0V, RP = 2.2k
IOUT = 250µA, BI = 0V, RP = 2.2k
VCC = 5V, TA = +25°C
0.15 0.20 0.25 mA
0.45 0.50 0.55 mA
0.90 1.00 1.10 mA
1.35 1.50 1.65 mA
– 0.8 2.5 V
– 0.003 3.0 µA
80 110 – V
– 0.4 10 µs
– 0.4 10 µs
RBI to Segment Output
– 0.7 10 µs
RBI to RBO
– 0.4 10 µs
Note 3. Unless otherwise specified, Min/Max limits apply across TA = 0° to +70°C. All typical values
are or TA = +25°C and VCC = 5V.
Note 4. All currents into device pins ahown as positive, out of device pins as negative, all voltages
referenced to GND unless otherwise sepcified. All values shown as Max or Min on absolute
value basis.
Note 5. For saturation mode the segment output currents are externally limited and ratioed.